Vent, Valve & Volt
Weak airflow from vents, or one room hotter or colder than the rest

You can fix this

Likely cause: ice on the coil is blocking air

Ice on the indoor coil acts like a wall that air can't get through. Thaw it, then find out why it froze.

Why this happens

Trane, Lennox and Carrier all list restricted airflow as a cause of a frozen coil, and once ice forms it cuts airflow even further. Tom's Guide quotes HVAC experts warning that closing vents can contribute to coil freezing. Carrier says a frozen AC will not fix itself.

How to fix it

  1. Set the thermostat from Cool to Off, then set the fan to On to thaw the ice. Carrier and Lennox both suggest this.
  2. Don't chip at the ice or use a hair dryer or heater on it.
  3. Put towels around the indoor unit and watch the drain pan as it melts.
  4. Work through the AC freezing up troubleshooter to find the cause before you run the AC again.

If this does not fix it, tell the HVAC technician

  • That airflow was weak at every vent and there was ice on the coil or lines.
  • Whether the filter was clean and every vent was open.
  • Whether it has frozen before.

Build the full list: what to tell the HVAC technician.