Furnace leaking water when the heat is on

You can fix this

Likely cause: the condensate pump

A pump that has lost power, sits off level, or has a stuck float lets its tank overflow. Little Giant's owner's manual covers checks you can make outside the furnace.

Why this happens

Where water can't drain by gravity, a small pump collects condensate in a tank and a float switch starts the motor. Bryant says a pump that fails, loses power or can't discharge lets its reservoir fill and overflow. Little Giant lists a pump that isn't level, debris on the float, a stuck check valve and a kinked outlet tube as causes of overflow, and says a dirty float can be too heavy to work. On models with a high-water switch wired into the thermostat circuit, Little Giant says the switch stops the system when the tank fills, so a furnace that stopped heating next to a full pump tank points here.

How to fix it

  1. Set the thermostat to Off so the furnace stops making water.
  2. These checks follow Little Giant's owner's manual for its VCMA pumps. If yours is another brand, use its own manual. If the pump has no plug and is wired in, don't open it. Little Giant notes more than one disconnect may be needed to cut its power, so call an HVAC technician.
  3. Little Giant says not to handle the pump with wet hands or while standing on a wet or damp floor, and not to touch the pump, its tubing or the water until it is unplugged. If the floor around the pump is wet, mop it from a dry spot first. If the outlet or cord is wet, don't touch it. Switch off that circuit's breaker only if you can reach the panel on a dry floor with dry hands, or leave it for the technician.
  4. With dry hands, unplug the pump. Then check that it sits flat. Little Giant says a pump that isn't level may not switch on.
  5. Follow the outlet tubing and straighten any kink. Little Giant says to clear tubing blocked by slime and debris.
  6. With the pump still unplugged, put on safety glasses, which Little Giant's manual calls for during maintenance. Snap the tank cover off as the manual shows, holding the cover level. Make sure the floats move freely.
  7. Clean the tank with warm water and mild soap and flush it with fresh water. Little Giant says this keeps acidic condensate from pitting the tank.
  8. Put the cover back and, with dry hands, plug the pump straight into its outlet. Little Giant says not to use an extension cord. Make sure its breaker is on, set the heat back on, and watch it cycle.

When to stop. If the motor won't start with a full tank after you've cleaned the floats and it has power, Little Giant lists a defective switch or motor and says to replace the pump. If it runs but won't empty the tank after cleaning, Little Giant points to a stuck check valve, a plugged impeller inlet or blocked tubing. Either way, call an HVAC technician.

If this does not fix it, tell the HVAC technician

  • The pump brand and model, and whether it hums, runs without pumping, or does nothing.
  • Whether it was level, plugged in, and whether the floats moved freely.
  • Whether the furnace stopped heating when the tank was full.

Build the full list: what to tell the HVAC technician.

Not quite what you are seeing? Other results in this troubleshooter: Gas smell or CO alarm: get outside now; Water near wiring or a leak you can't place: stop and call; The leak isn't the furnace: call a plumber; the furnace humidifier; a clogged or loose condensate drain; Frozen drain or a dripping vent pipe: call an HVAC technician; Water at a standard furnace: call an HVAC technician.

Start this troubleshooter over

FourHome is our sister brand. Browse all FourHome replacement faucet and shower parts on the FourHome Amazon store. We earn from purchases made through this link.